Technical Specifications| The total capacity of the mixer | 500ml | Motor power | 7.5KW |
| Power take-off speed | 2~150Rpm | Rotor ratio | 1:1.1 |
| Temp. control accuracy | ±1℃ | Torque sensor | Electronic direct-link torque measurement |
| Feeding port pressing method | Hydraulic pressing | The pressure of the pressing block on the material | 0.3~0.6Mpa |
| Cooling of the mixing chamber and the front and rear rotors | Water | Temperature control | 3-Zone |
| Maximum heating temperature | 350℃ | Torque measurement range | 0~500Nm |
| Torque measurement accuracy | 0.1~0.5%FS | Control mode | Manual, automatic, computer PLC |
| Computer measurement and control | Torque, temperature, rotational speed | Rotor type | Banbury |
| Control analysis software | Melting, Thermal Stabilization, Crosslinking, Superposition, Customization |
FAQ
What processes is the 0.5 L lab mixer used for?
Kneading, dispersing, mixing and plasticising of rubber, plastic raw materials and engineering modified compounds.
What tests can be run besides mixing?
Rheological characterisation of compounds, and crosslinking (curing) behaviour of thermoplastic materials.
What are the capacity and torque range?
Total chamber capacity 500 mL, torque range 0-500 N·m, accuracy 0.1-0.5% FS; motor power 7.5 kW.
What are the speed and temperature ranges?
Rotor speed 2-150 rpm, maximum heating temperature 350 °C, temperature accuracy ±1 °C.
How is the material pressed?
Hydraulic ram feeding, with a pressure of 0.3-0.6 MPa on the material. The chamber and rotors are water-cooled, with 3 temperature control channels.
What control modes and test modes are supported?
Manual, automatic and computer/PLC control. The analysis software covers melting, thermal stability, crosslinking, superposition and custom test modes. The computer monitors torque, temperature and speed.